20 000 USD Design on the site with seismicity of 9.3 points
Architectural DesignDesign, Calculation and Project Documentation. (Platz de la construction - Turkmenbashi)
Manufacturing building with reactant
Economy and storage
The Reagents. Transformation Substance
… Industrial building with a reactant mastery and a warehouse of reactants. Transformation Substance
-
112 USD Industrial water cleaning station
Architectural DesignClimate characteristics of the building area:
1) the normative wind pressure value for I wind area W0 = 0.23kPa (23 kg / m2);
2) the weight value of the snow roof for the IV snow area Sr = 2.4kPa (240kg / m2);
The temperature of the air of the coldest fifth is 0.98 - minus 38.
… The air temperature of the coldest dive is 0.98 - minus 42C
3) Seismicity of the construction district - 5 balls according to the map of the ZSR-97-A SNIP II-
7 to 8 *
The level of responsibility of the house is 2-normal.
The reliability ratio for responsibility is 1.0.
-
112 USD Transformer Substance TP-40
Architectural DesignClimate characteristics of the building area:
1) the normative wind pressure value for I wind area W0 = 0.23kPa (23 kg / m2);
2) the weight value of the snow roof for the IV snow area Sr = 2.4kPa (240kg / m2);
The temperature of the air of the coldest fifth is 0.98 - minus 38.
… The air temperature of the coldest dive is 0.98 - minus 42C
3) Seismicity of the construction district - 5 balls according to the map of the ZSR-97-A SNIP II-
7 to 8 *
The level of responsibility of the house is 2-normal.
The reliability ratio for responsibility is 1.0.
-
134 USD Centralized operating oil and chemical plant
Architectural DesignThe construction of a centralized operating oil and chemical plant.Climate characteristics of the building area:
1) the normative wind pressure value for the VI wind area W0 = 0.73kPa (73 kg / m2);
2) The normal weight of the snow roof on 1m2 of the horizontal surface of the land for the IV snow area Sg = 2,07 kPa (207 kg / m2);
3) The air temperature of the coldest dive is provided by 0.98 - minus 32 ° C.4) The air temperature of the coldest fifth with a supply of 0.98 - minus 29 ° C.5) Seismicity of the construction district - 7 balls according to the map of ZSR-97-A SNIP II- 7-81 *.According to the report on engineering and geological searches [7] the soil of the gliniste soil (IGE1-6) is referred to the III category for seismic properties.The level of responsibility of the house - elevations;
… The reliability ratio for responsibility is 1.1.The seismicity of the building is 8 balls.The maximum excess pressure at the front of the shock wave R = 100 kPa, the deflagration vibration is accepted according to the task on the design of the operating wave.
-
112 USD Customs - Buildings of Customs
The building is separated from the placed cabin for the central operating oil and chemical plant.
Climate characteristics of the building area:
1) the normative wind pressure value for the VI wind area W0 = 0.73kPa (73 kg / m2);
2) The normal weight of the snow roof on 1m2 of the horizontal surface of the land for the IV snow area Sg = 2,07 kPa (207 kg / m2);
… 3) The air temperature of the coldest dive is provided by 0.98 - minus 32 ° C.
4) The air temperature of the coldest fifth with a supply of 0.98 - minus 29 ° C.
5) Seismicity of the construction district - 7 balls according to the map of ZSR-97-A SNIP II- 7-81 *. According to the report on engineering and geological searches [7] the soil of the gliniste soil (IGE1-6) is referred to the III category for seismic properties. According to the task of the general officer, the seismicity of the building building - 8 balls.
The level of responsibility of the house is 2-normal.
The reliability ratio for responsibility is 1.0.
-
112 USD Block of Circular Water Supply Complex
Architectural DesignClimate characteristics of the building area:
1) the normative wind pressure value for I wind area W0 = 0.23kPa (23 kg / m2);
2) the weight value of the snow roof for the IV snow area Sr = 2.4kPa (240kg / m2);
The temperature of the air of the coldest fifth is 0.98 - minus 38.
… The air temperature of the coldest dive is 0.98 - minus 42C
3) Seismicity of the construction district - 5 balls according to the map of the ZSR-97-A SNIP II-
7 to 8 *
The level of responsibility of the house is 2-normal.
The reliability ratio for responsibility is 1.0.
-
112 USD Blocks of the production complex
Architectural DesignClimate characteristics of the building area:
1) the normative wind pressure value for I wind area W0 = 0.23kPa (23 kg / m2);
2) the weight value of the snow roof for the IV snow area Sr = 2.4kPa (240kg / m2);
The temperature of the air of the coldest fifth is 0.98 - minus 38.
… The air temperature of the coldest dive is 0.98 - minus 42C
3) Seismicity of the construction district - 5 balls according to the map of the ZSR-97-A SNIP II-
7 to 8 *
The level of responsibility of the house is 2-normal.
The reliability ratio for responsibility is 1.0.
-
58 USD Receipt - Cranovaya Floor
Architectural Design
Activity
| Latest proposals 4 | Budget | Added | Deadlines | Proposal | |
|---|---|---|---|---|---|
|
Визуалізація меблів з дерева (стиль мінімалізм)
10 USD
|
|||||
|
Визуализация интерьера кухни в классическом стиле
100 USD
|
|||||
|
3D design of furniture.
5 USD
|
|||||
|
Создать проект загородного дома
1600 USD
|