Zhenya Kolesnik
Rating
Skills and abilities
Writing
Portfolio
-
Examination of the heat-isolating coating of the building. Recommendations on C
Architectural Design
The tests are carried out in accordance with the state standards on natural testing methods. There is all the necessary instrumental base for conducting the surveys, as well as highly qualified staff capable of properly processing, interpreting and evaluating the results of the surveys, and giving recommendations.
-
Evaluation of moisture regime
Architectural Design
The evaluation of the moisture regime is carried out in accordance with the provisions and requirements of the state construction norms of Ukraine DBN V.2.6-31:2006 "Heat isolation buildings". I use software products that allow you to quickly and efficiently draw a conclusion about the moisture state of the designed or operated structure.
The absence of this assessment and the use of constructive solutions with a negative moisture mode can lead to the destruction of structures, moisture condensation, and the formation of mushrooms. I will help you protect yourself from these problems in the future by calculating and designing a design that meets the regulatory requirements.
-
Building two- and three-dimensional temperature fields
When conducting thermotechnical calculations to determine the given resistance of the heat transmission of the roofing structures, as well as when assessing the temperature characteristics of the roofing, it is impossible to do without the need to build two- and three-dimensional temperature fields. This need is also regulated by the requirements of the state construction norms of Ukraine DBN V.2.6-31:2006 "Heat isolation building", where it is clearly stated that the assessment is carried out "p.2.14 .... the results of calculations of two- and three-dimensional temperature fields.
To build temperature fields, I use software products that solve heat transfer tasks using mathematical modeling by methods of final variations. These programs are evaluated for adequacy using the validation examples provided in the relevant construction standards and standards.
-
Heat Technical calculations
Architectural Design
The conduct of heat-technical calculations is regulated by the requirements of the state construction norms of Ukraine DBN V.2.6-31:2006 "Heat isolation buildings". This document establishes the need to:
calculation of the thermal resistance of the roofing structures;
evaluation of the temperature characteristics of the roofs (temperature shift, minimum temperature on the inner surface);
… assessing the heat resistance indicators of roofs and premises, both in the summer and winter periods;
calculation of the air resistance of the roofing structures;
assessment of the moisture regime of the roofs;
The energy passport of the building.
The calculation and evaluation of the indicators listed must be carried out at the design stage, both the new construction and the reconstruction (thermoderation) of existing buildings.
I have great experience in carrying out such calculations and have all the necessary software to carry out them.
-
Project “Energy Efficiency”
Architectural Design
I provide services for the preparation of the “Energy Efficiency” section. My developments without problems go through examinations and checks for compliance with the standards of pre-project and project documentation. Please contact me, I will be glad to help you!
-
Calculation and preparation of the energy passport of buildings
Architectural Design
The energy passport of the building is a document containing the geometric, energy and thermal characteristics of the buildings and projects of the buildings, surrounding the structures and establishing their compliance with the requirements of the regulatory documents.
With us you are guaranteed to get the energy passport of the building!
Activity
| Latest proposals 2 | Budget | Added | Deadlines | Proposal | |
|---|---|---|---|---|---|
|
Расчет температурных полей
15 USD
|
|||||
|
Чертежи в Arhicad
5 USD
|