3D BIM model of the building (Revit)
Project Brief
1. General Requirements
Software: Autodesk Revit (version 2022+)
Model: LOD 300–350
Units: mm
Projections: plan, 4 facades, 2 sections, 3D
Coordination grid and axes are mandatory
All elements are separate families
2. Dimensions of the Building
Total width: 8352 mm
Total height: to be specified (base 3000 mm or according to the current version)
Depth: to be specified (≈4000 mm, final to be agreed)
3. Floor Panels and Walls
4 panels
Orientation: to be specified (2088×4000 or other current)
Panel frame:
Beam: 45×195 mm
Joist spacing: 400–600 mm (parametric)
Top sheet:
OSB 22 mm (or parameter “sheet material 22 mm”)
Must show:
ribs
perimeter framing
joints between panels
Walls 45x145+ OSB12mm and externally panels with vertical planking. Back wall height 2300, i.e., 7 degrees slope.
4. Front Facade Modules
Quantity: 6 pcs
Size of one module:
Width: 1372 mm
Height: 2500 mm
Frame:
Studs: 60×150 mm (alternative 50×150 — make parametric)
Top/bottom lintels: similar section
Provide load from the glazing unit (model without calculation, but geometrically correct)
5. Glazing Units
6 pcs
Dimensions: 1270×2400 mm
formula 6_14-20_6
Centering in the module
Gaps, bead - according to regulations
7. Mauerlat Beam (above the modules) and Pseudo Beams
Type: assembled insulated 50_50_50
Height: 300 mm
Thickness: 150 mm
Along the entire length of the facade
Must rest on the modules
At the joints of the roof panels, a box made of board 120*160 height., 3 pcs for 3 panel joints. or 50x160+80mm+50x160. the top of the beam aligns with the top of the mauerlat belt 300mm.
8. Roof Panels
Construction similar to floor panels
Beam 45×195 mm
OSB thickness according to standards to ensure minimal deflection.
Longer than the depth of the building (canopy)
Provide a niche for the awning
9. Canopy
Overhang: to be specified (≈300–400 mm)
Built-in awning (show as a conditional block)
Placement: above modules 2,3,4. ~4000mm
10. Covers at Joints (aluminum 1.2mm)
Width: 120 mm
Depth: 60 mm
On all vertical joints of the modules
Separate family
11. Materials (conditional)
Frame — pine
Panels — wooden frame
Glass — transparent
Cladding — parameter, planking 16x148
12. What Must Be Submitted
.RVT file
3D section showing the structure
Material specification * to be discussed
Volume table (wood volume, number of beams) *to be discussed
Export IFC
13. What is NOT Required
Visualization
Decor
Landscaping
Engineering (MEP)
14. Important
All dimensions are parameterized
Ability to change:
beam section
sheet thickness
module size
building depth
*added images are similar but not exact
-in proportions
-in the number of window modules (the one with the awning.)
Applications 2
-
974 29 1 1 Good day.
I will do the work quickly and efficiently.
Extensive practical experience.
I am engaged in architectural and construction projects, developing concepts of varying complexity, 3D modeling, 3D visualization, 3D video animation, project presentations, interior and exterior design, video editing, working with AI, as well as product design, developing furniture prototypes (designed and produced for an exhibition in Canada, after which they were launched into mass production), industrial design for mass production (developed street lighting installed in large quantities in various cities in different countries), product listing. Excellent knowledge of ergonomics, regulatory framework in the field of construction design. Extensive practical experience. Creative approach to work. I work in programs 3ds Max + V-Ray + Corona, SketchUp + V-Ray, AutoCAD, Revit, Photoshop, Lumion, After Effects, Archicad. My portfolioGoogle Drive
Google Drive
https://3ddomkiev.wixsite.com/website-2
Current freelance projects in the category Architectural Design
Adjustment of budget documentation (KL-0.4 kV)
56 USD
You need to make adjustments to the completed local budget and export the result in .btki (or .ims) format. You do NOT need to study the drawings or calculate the volumes of work independently — we have already conducted a full technical audit and prepared a step-by-step… Engineering, Architectural Design ∙ 9 hours 41 minutes back ∙ 2 proposals |
Refinement or development of the lighting project for an apartment (33m2) based on the existing design project.A ready design project for the apartment and a preliminary lighting project, completed as part of the design project. At this stage, there are doubts about certain lighting solutions, so a specialist in lighting design is needed to analyze the existing solution and, if… Engineering, Architectural Design ∙ 1 day 2 hours back ∙ 5 proposals |
Project of office mezzanine in the production hallPlease provide a quote for the design of a two-story office mezzanine that will be built in our new hall. Please include: 1. static calculations 2. preliminary space arrangement. A bathroom, kitchen, and employee dining area in accordance with health and safety regulations. The… Architectural Design ∙ 2 days 12 hours back |
Development of the KM section of the warehouse with an administrative partIt is necessary to develop the KM section of this project. The building is a warehouse with an administrative part, a metal frame, and sandwich panel cladding. The height is 5m to the lower chord of the truss. Architectural Design, Drawings & Diagrams ∙ 4 days 5 hours back ∙ 3 proposals |
PROJECT on External Water Supply and Sewage ZVK and KK
74 USD
It is necessary to develop a working project for sewage and water supply in Kyiv, Obolonsky district. The object is a warehouse. With approval (or without) from Kyivvodokanal. We provide the initial data. Length of sewage 70 linear meters, water supply 140 linear meters (bore… Engineering, Architectural Design ∙ 4 days 6 hours back ∙ 3 proposals |